WEN GN400iM Engine Will Not Start

Quick Answer: The WEN GN400iM engine will not start due to one of seven documented causes: engine switch set to STOP, fuel valve OFF, low oil, empty fuel tank, contaminated or old fuel, dirty or broken spark plug, or a carburetor air lock. Use observational checks below to identify the cause before attempting repairs.

Documented Possible Causes

According to the WEN GN400iM Instruction Manual, the following causes are associated with engine start failure:

  • Engine switch is set to STOP
  • Fuel valve is turned to OFF
  • Oil is low
  • Engine is out of fuel
  • Engine is filled with contaminated or old fuel
  • Spark plug is dirty or broken
  • Carburetor is air locked

Safe Observational Checks

Engine Switch Position

With the engine stopped and cool, visually inspect the engine switch. Confirm it is not in the STOP position. Refer to your operator manual for the correct switch position before attempting to start.

Fuel Valve Position

Locate the fuel valve on the engine. Visually confirm it is turned to the appropriate documented starting setting, not OFF. Do not disconnect or open the fuel system.

Oil Level

With the engine stopped and on level ground, locate the oil dipstick or sight glass. Check that oil level meets the minimum mark. The GN400iM oil capacity is 17.0 fl. oz. (0.5 L). Do not add oil while the engine is running or hot.

Fuel Tank Level

Visually inspect the fuel tank to confirm it contains fuel. The GN400iM fuel tank capacity is 1.85 US gallons (7.00 L). If the tank appears empty, refuel with 87 octane minimum gasoline.

Fuel Condition

If fuel has been stored in the tank for an extended period or appears discolored, contaminated, or has an unusual odor, the fuel may be old or contaminated. Refer to your operator manual for fuel storage and replacement guidance.

Spark Plug Inspection

The GN400iM uses a Torch F6RTC spark plug (NGK BPR6ES equivalent) with a gap of 0.7–0.8 mm (0.028–0.031 in.). Visual inspection of the spark plug for obvious damage, heavy carbon buildup, or corrosion can be performed with the engine stopped and cool. Do not perform electrical or spark tests. Refer to your manual for spark plug removal and inspection procedures, or contact a qualified technician.

Carburetor Air Lock

A carburetor air lock is not directly observable without disassembly. If all other checks are clear and the engine still will not start, consult your operator manual or contact WEN customer service at 1-800-232-1195 (M–F 8–5 CST) or techsupport@wenproducts.com.

Next Steps

After completing observational checks, refer to the WEN GN400iM Instruction Manual for detailed starting procedures and any model-specific troubleshooting. If the engine still does not start after addressing the identified causes, contact WEN customer service or consult a qualified small-engine technician.

Manual Disclaimer: This article references the WEN GN400iM Instruction Manual. For complete, model-specific procedures and safety information, consult the official manual at https://cdn.shopify.com/s/files/1/0012/0350/3168/files/GN400iM.manual.20220726.pdf?v=1707853002

Frequently Asked Questions

What is the correct spark plug for the WEN GN400iM?

The WEN GN400iM uses a Torch F6RTC spark plug (NGK BPR6ES equivalent) with a gap of 0.7–0.8 mm (0.028–0.031 in.).

What fuel type should I use in the WEN GN400iM?

Use 87 octane minimum gasoline. The fuel tank capacity is 1.85 US gallons (7.00 L).

What is the oil capacity for the WEN GN400iM?

The oil capacity is 17.0 fl. oz. (0.5 L). Check the oil level with the engine stopped and on level ground.

Who should I contact if my WEN GN400iM still will not start after troubleshooting?

Contact WEN customer service at 1-800-232-1195 (M–F 8–5 CST) or email techsupport@wenproducts.com for further assistance.

Source: Information adapted from official manufacturer documentation (reference). Always consult your generator owner’s manual for model-specific procedures.